| ALARM:1 |
HardLimit |
Observe whether the X-axis, Y-axis, or Z-axis limit switches are being triggered due to physical contact. |
| ALARM:3 |
AbortCycle |
This code is triggered when the engraving process is manually stopped and does not require clearing. |
| ALARM:5 |
ProbeFailContact |
Check whether the Z-axis limit switch has been triggered. |
| ALARM:8 |
HomingFailPulloff |
Homing failed due to limit switch reset failure. Check whether the machine stopped because a limit switch was triggered and whether the motion system is continuously triggering the limit switch. |
| ALARM:9 |
HomingFailApproach |
Please refer to the “Master Homing Failure” section. |
| ALARM:11 |
MachineTiltAlarm |
Tilt alarm detected. Place the machine back on a level surface and restart it. If the issue cannot be cleared, please send a video showing the problem and a photo of the machine’s Serial Number to customer service. |
| ALARM:12 |
FlameDetected |
Flame detection has been triggered. Restart the machine. If the alarm continues to trigger, please refer to the section “The Master Flame Detection Function Triggers False Alarms When No Fire Is Present” for troubleshooting. |
| ALARM:13 |
DoorOpen |
Enclosure open alarm detected. Please close the enclosure door. If the alarm still appears, check whether the limit switch is damaged. |